| نویسندگان | Mohammad Zare, Abolfazl Halvaei Niasar |
|---|---|
| همایش | 15th Iranian Student Conference on Electrical Engineering |
| تاریخ برگزاری همایش | August 2012 |
| محل برگزاری همایش | University of Kashan, Kashan, Iran |
| ارائه به نام دانشگاه | دانشگاه کاشان |
| نوع ارائه | سخنرانی |
| سطح همایش | ملی |
| کلید واژه ها | Induction Motor; DTC; FOC; Sector; Torque; Flux |
چکیده مقاله
The advantage of Direct Torque Control (DTC) of inverter-fed Induction Machine is high dynamic performance by means of very simple control structure. Using DTC technique, we can eliminate complexity of Field Oriented Control (FOC); but it doesn’t drive the Induction Machine as well as FOC. Recent researches have introduced improvements in DTC. In this paper we present a new DTC method with 12 sectors, in spite of 6 sectors in classical DTC, which make it more optimal.
متن کامل مقاله
لینک دانلود فایل