نویسندگان | Abolfazl Halvaei Niasar, and Behzad Habibzadeh Khoei |
---|---|
نشریه | Journal of Instrumentation Technology & Innovations |
شماره صفحات | 5-13 |
شماره سریال | 2 |
شماره مجلد | 5 |
نوع مقاله | Full Paper |
تاریخ انتشار | 2015 |
رتبه نشریه | علمی - پژوهشی |
نوع نشریه | الکترونیکی |
کشور محل چاپ | هند |
چکیده مقاله
This paper investigates the design and implementation of single-phase, three-level inverter controlled by sub-harmonic pulse width modulation (SH-PWM). The performance of developed 3-level inverter is simulated and then is compared with 2-level conventional inverter as well as FFT analysis. Experimental test has undertaken to examine the operating characteristics of the implemented inverter for supplying an inductive load. To increase the reliability of designed inverter in different applications, a short-circuit fault detection has been considered. Moreover, to reduce the voltage harmonic contents of inverter, a LC low pass filter is employed. Finally, an efficiency analysis is given to show the satisfactory performance of developed inverter.
tags: Three-level Inverter,Sub-harmonic PWM (SH-PWM),Total harmonic distortion (THD),Short-circuit fault detection,LC filter,H-bridge