نویسندگان | محسن محسن نیا,سیدحسین رسا,حمید مدرس |
---|---|
نشریه | Journal of Chemical & Engineering Data |
شماره صفحات | 1316 |
شماره مجلد | 51 |
ضریب تاثیر (IF) | ثبت نشده |
نوع مقاله | Full Paper |
تاریخ انتشار | 2006-06-09 |
رتبه نشریه | علمی - پژوهشی |
نوع نشریه | الکترونیکی |
کشور محل چاپ | ایران |
نمایه نشریه | JCR |
چکیده مقاله
The cloud-point temperatures and phase separation of (water + poly(ethylene glycol) + salt) ternary systems were studied by the refractometry method. The salts were K 3 PO 4 , K 2HPO4, Na 2 HPO 4, or Na 2CO3. The phase separation was also observed by visual inspection. Differences between the measured cloud point using the refractometry method, and visual inspection was up to (1 °C. The measured cloud-point temperatures are compared with those obtained by viscometry and laser beam scattering methods. These comparisons indicate complete agreement between the different methods for cloud-point temperature measurements for the (water + poly(ethylene glycol) + salt) ternary system. The salt-included liquid-liquid separation is studied by using the Flory-Huggins polymer solution theory. A simple linear temperature composition-dependent interaction parameter (¯) was applied for correlation of the measured cloud-point temperatures. The comparison between measured and correlated cloud- point temperatures indicates that average absolute deviation is less than 0.61 °C. Therefore, the Flory-Huggins model was successfully applied to determine the phase separation conditions of the (water + poly(ethylene glycol) + salt) ternary systems.
tags: Cloud-Point Measurements, Water + Poly(ethylene glycol) + Salt, Ternary Mixture System, Refractometry Method