A carbon paste electrode modified with multi-walled carbon nanotubes (CPE-MWCNTs) was prepared for
the simultaneous determination of tryptophan (Trp) and uric acid (UA). The surface morphology of the
modified electrode was characterized by scanning electron microscopy (SEM) and electrochemical
impedance spectroscopy (EIS). Cyclic voltammetry (CV), chronocoulometric and differential pulse
voltammetry (DPV) techniques were used to investigate the modified electrode for the electrocatalytic
oxidation of Trp and UA in aqueous solutions. Using the modified electrode the separation of the
oxidation peak potentials for Trp and UA was obtained to be 386.0 mV. Also the dynamic ranges for Trp
and UA were achieved to be 0.6–100.0 and 0.4–100.0 mM, respectively. The detection limits (S/N ¼ 3)