The use of multivariate voltammetric calibration for the simultaneous determination of two preserva-tives (methylparaben (MP) and propylparaben (PP)) in cosmetics is reported. At first, electrochemical
studies of MP and PP were done by cyclic voltammetry (CV), chronocoulometry (CHC) and linear sweep
voltammetry (LSV) techniques. Then central composite rotatable design (CCRD) and response surface
methodology (RSM) were used for simultaneous optimization of effective parameters on voltammetric
responses of the two analytes. The optimum values of pH, scan rate, step potential and pulse height
were 7.0, 0.062 V s−1 , 0.009 V and 0.07 V, respectively. After optimization, the resolution of the two mul-ticomponent mixtures has been accomplished by partial least squares (PLS) for voltammmetric studies of
them at the surface of a glassy carbon electrode. Finally, the proposed method was found to be applicable
for routine analysis (recovery tests) of the preservatives in a cosmetic product.