The present study is the first report on the effect of cetyltrimethylammonium
bromide (CTAB) on the electrochemical behavior of folic acid (FA) at the surface of
carbon paste electrode (CPE) in real samples. The studies were performed by cyclic
voltammetry (CV), chronocoulometry and differential pulse voltammetry (DPV).
CTAB, with a hydrophobic C-H chain, could absorb at the CPE surface by
hydrophobic interaction and then changed the electrode/solution interface, and
eventually affects the electrochemical response of FA, confirming from the
remarkable oxidation peak current enhancement. For investigation of the electrode
properties, CV technique was used at the various scan rates. Electrochemical
parameters including diffusion coefficient (D), electron transfer coefficient (α) and
ionic exchanging current density (jo) were determined for the FA at the surface of the
electrode. Under optimized conditions, the proposed method showed acceptable analytical performances for FA in terms of linearity (over the concentration range
from 0.01 -1.5 and 1.5 -10.0 μM), detection limit (2.89 nM), repeatability (1.37%)
and stability (13% reduction in peak current after 60 days). After studying on the
effect of probable interferences it was found that the method was free of the
interferences. Finally, the proposed method was successfully applied for the
determination of FA in real samples