Determination of Bromate Ions in Drinking Water by Derivatization with 2-Methyl-2-Butene, Dispersive Liquid-Liquid Extraction and Gas Chromatography- Electron Capture Detection

نویسندگانMehdi Nabi, Sayed Mehdi Ghoreishi,* and Mohsen Behpour
نشریهJournal of AOAC INTERNATIONAL
ارائه به نام دانشگاهkashan
شماره صفحات1-7
نوع مقالهFull Paper
تاریخ انتشار18-1-2020
رتبه نشریهISI
نوع نشریهالکترونیکی
کشور محل چاپآروبا

چکیده مقاله

Background: A simple, rapid, selective and sensitive sample preparation and derivatization method was performed for
determination of bromate ions in water by means of dispersive liquid-liquid extraction (DLLE) by gas chromatographyelectron
capture detection (GC-ECD). This method is based on 2-methyl-2-butene derivatization by bromine produced from
bromate ions in acidic medium and extraction by n-hexane.
Objective: Derivatizing agent: It is cheap and available and it has high efficiency in reaction with Br2. Simplicity: Preparation
and extraction process don’t need to any specific equipment and procedure is completely simple and fast. Limit of
detection: DL is as low as 0.43 mg/L.
Methods: Various effective factors on the derivatization and extraction efficiency, such as amount of derivatizing agent,
volume of extraction solvent, bromide concentration, volume and concentration of sulfuric acid, type and volume of
extracting and dispersing solvent, ionic strength, storage time before extraction and ECD makeup-gas flow rate were
investigated.
Results: Under the optimum conditions, the method had a linear calibration curve ranging from 1.0 to 200.0 mg/L for
bromate ions with a determination coefficient (R2) of 0.994 and the detection limit was 0.43 mg/L. The recovery percent and
relative standard deviation for the determination of 1.0, 5.0 and 50.0 mg/L bromate ion was between 90 and 110%, and 3.0
and 8.0% (n¼3), respectively.
Conclusions: Finally, the method was successfully applied for the preconcentration and determination of bromate ions in
water samples, and satisfactory results were obtained.
Highlights: (1) Fast, easy, accurate and economical innovative analysis of bromate ions in water and wastewater.
(2) Determination of inorganic ion by GC-ECD after derivatization (3) Low detection limit (4) Optimization of different
method parameters to obtain accurate results based on requirements of international standards, specifically ISO/IEC
17025.