نویسندگان | فهیمه طاهرنژاد جوزمی,مهدی شبانی نوش آبادی,حسن کریمی مله |
---|---|
نشریه | COMPOS PART B-ENG |
شماره صفحات | 666 |
شماره مجلد | 2019 |
ضریب تاثیر (IF) | 6.864 |
نوع مقاله | Full Paper |
تاریخ انتشار | 2019-05-11 |
رتبه نشریه | علمی - پژوهشی |
نوع نشریه | الکترونیکی |
کشور محل چاپ | ایران |
نمایه نشریه | SCOPUS ,JCR |
چکیده مقاله
This paper reports an electroanalytical sensor developed based on reduced graphene oxide/FeNi3 (FeNi3/rGO)- ionic liquid (n-hexyl-3-methylimidazolium hexafluoro phosphate (HMPF6) carbon paste electrode (CPE) for determining the antioxidant additive tertbutylhydroquinone (TBHQ) in the presence of folic acid. The FeNi3/rGO synthesized by hydrothermal strategy and characterized by X-ray diffraction (XRD) and FESEM methods. The electrochemical response were found to be linearly symmetrical to TBHQ and folic acid concentrations in the range from 0.05 to 900 μM and 0.6–1100 μM with detection limits of 10.0 nM and 0.1 μM, respectively. The FeNi3/rGO/HMPF6/CPE showed high-quality for determination of TBHQ in the presence of folic acid in the real samples with the separation potential ~600 mV.
tags: TBHQ Folic acid Reduced graphene oxide/FeNi3 Hydrothermal