چکیده مقاله
Abstract
Purpose – Using passive techniques like twisted tapes and corrugated surface is an efficient method of heat transfer improvement, since the referred manners break the boundary layer and improve the heat exchange. This paper aims to present an improved dual-flow parabolic trough collector (PTC). For this purpose, the effect
of an absorber roof, a type of turbulator and a grooved absorber tube in the presence of nanofluid is investigated
separately and simultaneously.
Design/methodology/approach – The FLUENTwas used for solution of governing equation using control
volume scheme. The control volume scheme has been used for solving the governing equations using the finite
volume method. The standard k–e turbulence model has been chosen.
Findings – Fluid flow and heat transfer features, as friction factor, performance evaluation criteria (PEC) and
Nusselt number have been calculated and analyzed. It is showed that absorber roof intensifies the heat transfer
ratio in PTCs. Also, the combination of inserting the turbulator, outer corrugated and inner grooved absorber
tube surface can enhance the PEC of PTCs considerably.
Originality/value – Results of the current study show that the PTC with two heat transfer fluids, outer and
inner surface corrugated absorber tube, inserting the twisted tape and absorber roof have the maximum Nusselt
number ratio equal to 5, and PEC higher than 2.5 between all proposed arrangements for investigated Reynolds
numbers (from 10,000 to 20,000) and nanoparticles [Boehmite alumina (“λ-AlOOH)”] volume fractions (from
0.005 to 0.03). Maximum Nusselt number and PEC correspond to nanoparticle volume fraction and Reynolds
number equal to 0.03 and 20,000, respectively. Besides, it was found that the performance evaluation criteria
index values continuously grow by an intensification of nanoparticle volume concentrations.