چکیده مقاله
Effects of different entry/exit arrangements on thermal
performance of porous microchannel heat sink (MCHS)
of any geometry have not been studied yet. In this
investigation, the effects of utilization of four different
entry/exit arrangements have been studied numerically
on electronic chip cooling utilizing trapezoidal MCHS
with porous micro channels and porosity of 0.88. In Atype
arrangement (Figure 1), entry and exit are located in
the center of the northern and southern walls,
respectively. Entry and exit in B-type heat sink, in
contrast to A-type, have been moved to the corners
asymmetrically from the center of the northern and
southern walls. Both Entry and exit in C-type are located
in the western wall respectively in the center of the
distributor and flow collector. In D-type heat sink, the
exit has not changed compared with the C-type, but the
entry has been moved to the eastern wall. For this
purpose, three dimensional simulations of laminar forced
convection flow in microchannels and conduction in
solid parts of MCHS by applying constant heat flux of
150 kWm-2 at its base plate have been performed
utilizing the finite volume method and the commercial
Ansys-CFX code. The results indicate that using porous
media is effective in reducing the MCHS base plate
temperature and in this regard the D-type arrangement
has the best performance among the heat sinks studied.
With considering positive effect of using porous media
on increasing the heat transfer coefficient and its
negative effect on increasing the required pumping
power, the A-type arrangement has the best performance.